« KSB Series »  


KINGTEC-KSB


    Zoom


    Technical Drawing

    Back

SUPER-SLIM TYPE FIBER-GLASS ROOF-MOUNTED
AIR-CONDITIONING UNIT
ITEM UNIT TECHNICAL PARAMETER
MODEL   KSB09 KSB10 KSB11
COOLING CAPACITY W 28000 31000 33000
BTU/h 96000 106000 113000
REFRIGERANT   R134a
REFRIGERANT CHARGE Kg 6.5 8 8
MODEL   4PFCY 4NFCY 4NFCY
DISPLACEMENT cm3 558 647 647
LUBRICANT   BSE55 2.5L
CLUTCH POWER W 60 60 60
VOLTAGE V 24V/DC
WEIGHT Kg 34 33 33
TYPE   TUBE AND FIN (WHORLED IN TUBE, HYDROPHILIC ALUMINUM FOIL)
AIR FLOW RATE m3/h 4020 6000 6600
CURRENT A 48 66 72
TYPE   TUBE AND FIN (WHORLED IN TUBE)
AIR FLOW RATE m3/h 7200 9600 9600
CURRENT A 22.5 30 30
TOTAL CURRENT A 72 98 104
CONDENSER LENGTH (1) mm 1770 1910 1910
EVAPORATOR  LENGTH (1) mm 1950 2375 2375
WIDTH mm 1860 1970 1870
HEIGHT mm 175 172 172
WEIGHT Kg 208 235 238
INSIDE TEMPERATURE °C ADJUSTABLE FROM 18°C TO 28°C
DEFROST TEMPERATURE °C 1 ~ 3
AIR FLOW   3 STEP CONTROL: HIGH, MIDDLE, LOW
SAFETY DEVICE

HIGH PRESSURE SWITCH

MPa ACTION PRESSURE 2.35MPa, RESET PRESSURE 1.65MPa

LOW PRESSURE SWITCH

MPa ACTION PRESSURE 0.04MPa, RESET PRESSURE 0.14MPa